Nke aCAT7A Bulk Ethernet Cable, 10G Ime ụlọ / N'èzí Dual Shield Solid Copper S / FTP, 23 AWG 1000ftbụ 10G Ime ụlọ / N'èzí Dual Shielded Solid Copper S / FTP, 23 AWG 1000FT na-anwale maka bandwidth ruo 1000MHz. Tụkwasị na nke a, eriri ntanetị a nwere ụzọ anọ nke 23 AWG siri ike na-eduzi ọla kọpa nwere onye ọ bụla na-echekwa ihe mkpuchi ma na-ere ya na 1,000 ụkwụ.
1.Okwu Mmalite nkeCAT7A Bulk Ethernet Cable, 10G Ime ụlọ / N'èzí Dual Shield Solid Copper S / FTP, 23 AWG 1000ft
Nke aCAT7A Bulk Ethernet Cable, 10G Ime ụlọ / N'èzí Dual Shield Solid Copper S / FTP, 23 AWG 1000ftbụ nnukwu ọsọ 10 Gigabit F-Type Bulk Cable nke mejupụtara nhazi 4 Mmakọ / 8 Conductor. Augdị F-Type a gbara agba nwere jaket dị n'ime ya nke na-enye ohere maka bandwidth ngwa ngwa (ruo 1000 MHz na Augment CAT7). A na-echebe abụọ ndị a gbagọrọ agbagọ n'otu n'otu iji gbochie nnyonye nke electromagnetic (EMI) na gburugburu ebe a na-anụ ọkụ. Ezubere CAT7A Cable a yana Tin-Copper Braid n’ozuzu ya maka nchebe nnyonye anya ọzọ. Tụkwasị na nke a, eriri a nwere waya ọla kọpa ọla kọpa nke na-agbanye ọkụ eletrik mgbe emechara ya. Achọrọ waya drain a na eriri ọta ọ bụla iji gbochie mgbaàmà mgbaàmà, ikwu okwu na nsogbu ndị ọzọ. Nke a bụ CAT7A Cable bụ 23AWG ma mejupụtara Solid-Bare Copper Conductors na akwa ojii, anwụrụ ọkụ efu halogen (LSZH). Igwe a dị na 1000 'increments na Wooden Spool.
2.NgwaahịaOke (nkọwapụta) nkeCAT7A Bulk Ethernet Cable, 10G Ime ụlọ / N'èzí Dual Shield Solid Copper S / FTP, 23 AWG 1000ft
Nduzi Size |
23 AWG |
Ihe Nduzi |
SolidEzigbo Copper |
Ihe mkpuchi |
Skin-amfụfụ-Skin Polyethylene |
Mkpuchi dayameta |
1.330 ± 0.05mm |
Ọnụ ọgụgụ ndị na-eduzi ya |
8 |
Ọnụ ọgụgụ abụọ |
4 |
Achịkọ Njikọ Abụọ |
AL / Mylar |
Ihe Shield Mpụga |
TC ịkpa |
Elu jaket Ihe |
CM PVC (Complies RoHS) |
Mpụga jaketị mpụta |
7.5mm ± 0.5mm |
Mpụga Jacket Rip Cord |
Eeh |
3.NgwaahịaNjirimara na Ngwa nkeCAT7A Bulk Ethernet Cable, 10G Ime ụlọ / N'èzí Dual Shield Solid Copper S / FTP, 23 AWG 1000ft
• Nzute ma ọ bụ karịa CAT 7A T568C.2 ardskpụrụ
• Dị Mfe Iji Jiri Osisi Spool
• Extra Headroom enye ụlọ maka uto
• Attenuation Obere na Ike-Sum Crosstalk
4.NgwaahịaDetails of the CAT7A Bulk Ethernet Cable, 10G Ime ụlọ / N'èzí Dual Shield Solid Copper S / FTP, 23 AWG 1000ft
Nke a CAT7A Bulk Ethernet Cable, 10G Ime ụlọ / N'èzí Dual Shield Solid Copper S / FTP, 23 AWG 1000ft ime ụlọ 10G (S / FTP) arụmọrụ dị elu
data nkwukọrịta USB nwere olu, data, vidiyo
na ikike nchekwa ma dị mma maka netwọk
echichi. Ezubere eriri USB a maka ụdị ụlọ
nrụnye. Nke anyiCAT7A Bulk Ethernet Cable, 10G Ime ụlọ / N'èzí Dual Shield Solid Copper S / FTP, 23 AWG 1000ftnwere 4 ụzọ abụọ
23AWG siri ike na-eduzi ọla kọpa, n'otu n'otu
echebe ọta abụọ na ngụkọta TC ịkpa isi, na
Ihe mkpuchi PVC RoHS kwekọrọ. Igwe ikuku anyị bụ
Ejiri ya na 1000ft spool spool ma kaa akara
na-agbadata ka ị wee mara ego ole
USB hapụrụ.
5.NgwaahịaQualification of the CAT7A Bulk Ethernet Cable, 10G Ime ụlọ / N'èzí Dual Shield Solid Copper S / FTP, 23 AWG 1000ft
Nke aCAT7A Bulk Ethernet Cable, 10G Ime ụlọ / N'èzí Dual Shield Solid Copper S / FTP, 23 AWG 1000ft soro UL RoHS kwadoro & ISO9001: 2015 kwadoro
6.yepụta, Mbupu na Ijere nkeCAT7A Bulk Ethernet Cable, 10G Ime ụlọ / N'èzí Dual Shield Solid Copper S / FTP, 23 AWG 1000ft
Lead time:15 days for 10K 1000ft CAT7A Bulk Ethernet Cable, 10G Ime ụlọ / N'èzí Dual Shield Solid Copper S / FTP, 23 AWG 1000ft
7. Ajụjụ
1. Ajụjụ: Gịnị bụCAT7A Bulk Ethernet Cable, 10G Ime ụlọ / N'èzí Dual Shield Solid Copper S / FTP, 23 AWG 1000fteji maka?
A:CAT7A Bulk Ethernet Cable, 10G Ime ụlọ / N'èzí Dual Shield Solid Copper S / FTP, 23 AWG 1000ftawade arụmọrụ nke ihe ruru 600MHz, 10G
2.Q:Does CAT7A Bulk Ethernet Cable, 10G Ime ụlọ / N'èzí Dual Shield Solid Copper S / FTP, 23 AWG 1000ftna-akwado 10gb?
A: CAT7A Bulk Ethernet Cable, 10G Ime ụlọ / N'èzí Dual Shield Solid Copper S / FTP, 23 AWG 1000ftnwere ike ịkwado 10 Gbps, mana nyocha ụlọ nyocha gosipụtara nke ọma ikike ya ịnyefe 40 Gb na 50 mita na ọbụlagodi 100 Gb na 15 mita.
3.Q:What's the difference between CAT5, CAT6 CAT7 and CAT7A Bulk Ethernet Cable, 10G Ime ụlọ / N'èzí Dual Shield Solid Copper S / FTP, 23 AWG 1000ft?
A;
·Nchịkwanwere bandwidth nke 100 MHz, ma na-abawanye akara mbufe na-agba ọsọ na mbelata mkpọtụ ma belata nnyonye anya mgbaàmà.
·Cat6-N'adịghị ka Cat5 na Cat5e, Cat6 nwere ikike iji belata crosstalk. Atiya 6 nke udi na-ekwusi ike na bandwidth nke 200 MHz ma na-arụpụta nnukwu ọsọ n'ozuzu ya.
·Cat6a-Site na bandwidth nke 500 MHz, Cat6a karịrị okpukpu abụọ bandwidth nke Cat6 cabling. Okpukpo a na-ekpuchi ahihia na-ebelata ụzọ ndị ọbịa ma ọ na-eme ka ọ dị ntakịrị mgbanwe. Agbanyeghị, nhọrọ a na-enyekwu ntụkwasị obi gbasara ọsọ, n'agbanyeghị gburugburu.
·Cat7na-etinye wires ejiri kpuchitere n'ụzọ zuru ezu, nke akpọrọ Screen Shielded Twisted Pair (SSTP) ma ọ bụ wired ekpuchi ihu abụọ (SFTP), na-ebute ọkwa arụmọrụ dị elu. Site na bandwidth 600 MHz, Cat7 na-enye ohere maka nnyefe data ọsọ ọsọ ọsọ ọsọ ma nwee ike ijikwa ọtụtụ nnyefe ozi. Otu udi nke 7 bu nnukwu ego, ebe o nwere onu ogugu nke 15 afọ, ma o megide onu ogugu ndu ndu nke 10 nke uzo mbu.
·Cat7A na-etinye wires ejiri kpuchitere n'ụzọ zuru ezu, nke akpọrọ Screen Shielded Twisted Pair (SSTP) ma ọ bụ wired ekpuchi ihu abụọ (SFTP), na-ebute ọkwa arụmọrụ dị elu. Site na bandwidth 1000 MHz, Cat7 na-enye ohere maka nnyefe data ọsọ ọsọ ọsọ ọsọ ma nwee ike ijikwa ọtụtụ nnyefe ozi. Otu udi nke 7 bu nnukwu ego, ebe o nwere onu ogugu nke 15 afọ, ma o megide onu ogugu ndu ndu nke 10 nke uzo mbu.